E/One Extreme Series Grinder Pump
E/One Extreme Series Grinder Pump
All E/One grinder pump systems currently offered use the Extreme Series grinder pump.
The grinder pump turns on and off automatically and runs for very short periods several times per day. Electrical consumption is low — a household that uses 250 gallons of water per day should use between 6 kwhr and 23 kwhr per month to run the pump. (Actual water and power usage will vary depending on the system pressure.)
Operational Information
Motor: 1 HP, 1725 rpm, high torque, capacitor start, thermally protected, 240 or 120 volt, 60 hertz, 1 phase
Discharge:
15 gpm at 0 psig
11 gpm at 40 psig
7.8 gpm at 80 psig
Electrical Information
For a standard 240V single-phase installation, a dedicated 30A breaker is required, with #10 wire, to the E/One panel. You need to bring L1, L2, N and Gnd.
If only 208V power is available, a buck boost transformer is required to boost 208V to 240V. The E/One pump requires a minimum of 216V to start and run reliably.
Type: | |
---|---|
Vendor: | |
SKU: |
UD200A01A01AA , S256748 |
Weight: |
92.0 lb |