DUPLEX 3Ø CONTROL PANEL 16 TO 20 AMP RANGE # BF3FD-D740-16-20 Model BF3ED-D740-16-20, 16.0-20.0 amps, 5 HP 208 volts 3Ø, 5 HP 230 volts 3Ø and 10 HP 460 volts 3Ø.
DUPLEX 3Ø CONTROL PANEL 16 TO 20 AMP RANGE # BF3FD-D740-16-20
Model BF3ED-D740-16-20, 16.0-20.0 amps, 5 HP 208 volts 3Ø, 5 HP 230 volts 3Ø and 10 HP 460 volts 3Ø. Duplex waterproof control panels with hand-off-auto switches, running lights, (H-O-A) elapse time meters for each pump plus a visual flashing high water alarm, and a pulsating high water alarm horn with silence button in a Nema 4X water-proof fiberglass enclosure for a variety of sump, effluent, sewage and water transfer applications.
Specifications
NEMA 4X fiberglass enclosure with gasketed hinged door and stainless steel hardware and lockable latch. Application: Superior quality duplex level controller for a variety of sump, effluent, sewage and water transfer applications. Three Level Floats Operation: Float #1: Both pumps off; Float #2: Lead pump on; Float #3: Lag pump and visual & audio alarms on. Four level floats operation: Float #1: Both pumps off; Float #2: Lead pump on; Float #3: Lag pump on. Float #4: Visual & audio alarms on. Exterior Mounted Components: Elapsed time meters for each pump; Running lights for each pump; Silence switch for manual silence of alarm horn; Alarm test switch for tested alarm circuit; Red high intensity manual reset alarm light (top mounted); Pulsating, corrosion proof 30 Watt, 95 dB. automatic reset alarm horn. Interior Mounted Components Magnetic contactors; Adjustable motor protectors (3 phase controls only); 115 volts control transformer (3 phase controls only); Toggle switches mounting plate: H-O-A (Hand-Off-Auto)switch for each pump; On-off control circuit switch; Electronic control board: Solid state pump alternator displays float status; Alternator selector switch. Choice of alternation or only one pump operation; Lag pump 5 second lag start relay; Auxiliary alarm contacts provided for remote control connection; Color coded wiring, screw type terminals and plug-in sockets Single Phase Power Feed: Field adjustable for 115 or 230 Volts 60 Hz. Three Phase Power Feed: Field adjustable for 208/230/460/575 Volts 60 Hz Note: Panel can be wired for a single power feed and control circuit or it can be wired to a separate power supply to insure alarm integrity in case of a tripped main breaker. Documentation Field wiring diagram; Panel schematic; Installation instructions. Certifications Entire unit is UL and cUL listed
Type: | |
---|---|
Vendor: | |
SKU: |
BF3FD |
Weight: |
42.0 lb |